Hello all...
H:0x2 | BUS stayed busy through time out period |
H:0x8 | The SCSI bus (or this device) has been reset. Any SCSI device on a SCSI bus is capable of instigating a reset. |
D:0x2 | CHECK CONDITION |
h:0xc | This status is returned due to a transient error. When this status is returned, the I/O command is requeued and issued again. |
Been noodling on these entries for awhile now :
2013-12-11T06:08:06.656Z cpu27:16411)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237:NMP device "naa.600507680192015950000000000011a1" state in doubt; requested fast path state update...
2013-12-11T06:08:06.656Z cpu27:16411)ScsiDeviceIO: 2318: Cmd(0x4124803fd100) 0x2a, CmdSN 0xa192000 from world 1270388 to dev "naa.600507680192015950000000000011a1" failed H:0x2 D:0x0 P:0x0 Possible sense data: 0x0 0x0 0x0.
2013-12-11T06:08:06.658Z cpu27:16411)NMP: nmp_ThrottleLogForDevice:2319: Cmd 0x28 (0x4124803f6000, 16866) to dev "naa.600507680192015950000000000008f4" on path "vmhba1:C0:T1:L2" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x0. Act:NONE
2013-12-11T06:08:06.658Z cpu27:16411)ScsiDeviceIO: 2318: Cmd(0x4124803f6000) 0x28, CmdSN 0x16a75f6 from world 16866 to dev "naa.600507680192015950000000000008f4" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x0.
2013-12-11T06:08:06.658Z cpu27:16411)ScsiCore: 1483: Power-on Reset occurred on naa.600507680192015950000000000008f4
2013-12-11T06:08:06.659Z cpu13:16932)ScsiCore: 1483: Power-on Reset occurred on vmhba1:C0:T1:L0
we even get H:0x8 and H:0xc as well as D:0x2:
Are these normal ? given that in 1 vmKernel log file we get over 400 H:0x2 entries in one host...we have 4 currently.
Does this mean our SAN / SVC is unable to accomodate the load?
or Could there be something in vmware/vcenter v5.1 esx 5.1 that we can configure/upgrade/
are these entries probable/ or actual cause for VMs freezing/slowing down for 15secs or more ?
please advise...
thank you,
Kahlil