Re: Configure multiple initiator zoning to single initiator zoning
Welcome to communities! If the hosts are able to see the same LUNs and paths after zone re-config, then everything should be OK. They will see the same datastores and content.If your FC switch does not...
View ArticleRe: iSCSI Port Binding Question
Currently it looks like you have iSCSI ports on 4 subnets.The keywords here are "routing is not supported with port binding".By "same broadcast domain" here we mean that all bound vmk ports and all...
View ArticleRe: iSCSI Port Binding Question
Thanks for the reply, Dell initially set up SAN using the this configuration. I think you're right in that the all ports are advertised but the ESXi won't be able to access them. What are my options...
View ArticleRe: iSCSI Port Binding Question
first of all iscsi dont need any separate vlans for each iscsi target ports, that is a single vlan is enough.Here you have total 8 ports in the iscsi storage side, and you need to have 8 pnics and 8...
View ArticleRe: iSCSI Port Binding Question
Is the array already in production?What was the reason for configuring each array port in different subnet? Are there any requirements behind this or was it done "just because one felt doing so"? If...
View ArticleRe: iSCSI Port Binding Question
Gopinath Keerthyrajan wrote: Here you have total 8 ports in the iscsi storage side, and you need to have 8 pnics and 8 vmkernel ports in the esx side, then only you will get the full bandwidth. that is...
View ArticleRe: iSCSI Port Binding Question
Can this be resolved by only using Static Discovery rather than Dynamic, so the unreachable iSCSI targets are not listed? That would reduce the number of targets from 8 to 4 that the host is aware of,...
View ArticleRe: iSCSI Port Binding Question
In effect it would look like this: ESXi host:vSwitch1vmk1 IP: 192.168.132.105 (Port Binding vmnic 1)vmk2 IP: 192.168.132.106 (Port Binding vmnic 2)Storage array:Controller...
View ArticleRe: iSCSI Port Binding Question
Yes, static discovery could do the trick. But still, if you're doing port binding then all vmkernel ports used by SW iSCSI initiator need to be on same subnet which leaves you on using single port per...
View ArticleRe: iSCSI Port Binding Question
kermic wrote: I strongly disagree with this one. This will be true only if:there is a single host accessing arraythere are at least 8 luns on array, all accessed at full throttle at the same time,...
View ArticleRe: iSCSI Port Binding Question
if you are using ISCSI HBA or ISCSI offload in the pnic then only you can have the static discovery, if you are using software iscsi ininitiator then you can only have dynamic discovery, let me know...
View ArticleRe: iSCSI Port Binding Question
kermic - thanks have been reading the whitepaper from Dell on the MD3220i and ESXi 5.0 Gkeerthy - I didn't know that was the case with static and dynamic discovery , I was planning to use the software...
View ArticleRe: iSCSI Port Binding Question
if you have iscsi offload try to use them, also check the performance of the software and hardware initiators.
View ArticleRe: iSCSI Port Binding Question
http://i.dell.com/sites/content/shared-content/data-sheets/en/Documents/PowerVault_MD_iSCSI_Deployment_Guide_for_VMware_ESX50_Server_Software.pdf...
View ArticleRe: iSCSI Port Binding Question
I'm not saying you're completely wrong.However noone here mentioned issues related to link saturation, yet Theoretically array with 8x1Gbps ports can produce 8Gbps throughput. Agreed?Would you buy an...
View ArticleRe: iSCSI Port Binding Question
Thanks jsut re-reading them all again as I'm starting to get a better understaning, one point in the Dell Deployment Guide is "Configuring hardware initiators from within VMware® ESXi5.0 Server™ is...
View ArticleRe: iSCSI Port Binding Question
Gopinath Keerthyrajan wrote: if you are using ISCSI HBA or ISCSI offload in the pnic then only you can have the static discovery, if you are using software iscsi ininitiator then you can only have...
View ArticleRe: iSCSI Port Binding Question
if it is a regular vms..ok..i agree, but if it is a prodcution vms with heavy load and if you will get bottleneck. more over, why we need to limit, if the hardware is capable, we need to use. I know...
View ArticleLimiting IO per VM
What is the best way to limit the IO a VM can generate to a shared nfs datastore? We have been setting limits on the number of IOPs per vmdk at the vSphere layer (sched.scsiX:X.throughputCap in the...
View ArticleRe: Configure multiple initiator zoning to single initiator zoning
Thanks kermit on the reply. Appreciate your help! I will try to re-configure single initiator zoning tomorrow. I would probably prefer to unmount the datastore first, re-configure zoning and mount...
View Article