Re: Duplicate LUN ID from different iSCSI Target

$
0
0

Hussain Al Sayed wrote:

 

Found that the VNXe3150 generating LUN ID based on the LUN that's owned by which controller. If LUN created and pointed to SPA and the LUN ID generated as 0 then the second LUN that will be owned by SPB it will be 0 as well. VNXe3150 contradictory.

 

I agree that it is nice to be able to select the LUN id manually, but the LUN number should by definition be relative only to the SCSI or iSCSI target and from that it would not be wrong for the 3150 (with dual SP) to present two different disks with the same LUN number if they are bound to different storage processors ("targets").