Re: Deploying templates to local disks?

Hi Friend,    PLz see which datastore the VM is resided (the VM whose template you are creating) & select the same datastore for placing the template.

View Article


Re: HP VSA 11.0 (2014) - Bad storage performance

I am still using older version.. planning to upgrade.. Will check the issue

View Article


Image may be NSFW.
Clik here to view.

A few questions about ESXi queueing

Hi, a few questions about queues in ESXi for the storage gurus : 1. What is the relation between WQLEN value shown in ESXTOP and Maximum Outstanding Disk Requests (described in VMware KB:    Setting...

View Article

Image may be NSFW.
Clik here to view.

Mapped Raw LUN issue - I can't increase the size.

Hello, I am having trouble increasing the disk size on one of our servers because it is running out of room. The disk I need to increase is a Mapped Raw LUN device though (Raw device mapping). I went...

View Article

Re: HP VSA 11.0 (2014) - Bad storage performance

I've learned that we can best reproduce the errors and storage delays when running a robocopy task that generates a lot of storage throughput while the host is also running many other VM's. The problem...

View Article


Re: Mapped Raw LUN issue - I can't increase the size.

To increase a RDM, you need to increase that specific LUN on the storage, and not a datastore, although a .vmdk file - which is created for a  RDM - is located on a datastore. This is only a mapping...

View Article

Re: Deploying templates to local disks?

That was it. Exactly as I was expecting, I was missing something, and you guys pointed out exactly what I did wrong.I was selecting the cluster instead of a single host.If I select a single host...

View Article

Re: Deploying templates to local disks?

Yes that is correct.

View Article


Software to handle CIFS and NFS on VMWare?

Does anyone have experience using software to setup CIFS and NFS on VMware?

View Article


expanding vmware lun without extents

Is it possible to expand a lun without using extents?

View Article

Re: expanding vmware lun without extents

Hi Friend,VMware vSphere cannot modify the size of a LUN or other storage device on the array. Modifying the size of an array device must be done using the storage array vendor's management tools....

View Article

Re: Software to handle CIFS and NFS on VMWare?

Hi Friend,   I am not sure, I am following your question: On NFS:do you mean,1.how to mount the NFS datastore? 2. How to deploy NFS devices in a VM ie.Open filers etc.. I am not aware @CIFS.

View Article

Re: A few questions about ESXi queueing

Hi Friend, 1. Just go through these QUEUE terminologies given below and then read KB again :AQLENThe storage adapter queue depth. This is the maximum number of ESX Server VMKernel active commands that...

View Article


Design question about new BIG vmdks

We are revising out storage configuration with new ESXi5.5 allowing up to 62TB VMDK , and would like you opinion about this for a special application we host . OS > Datastores  we always keep 10 %...

View Article

Re: Design question about new BIG vmdks

I do not have specific answer to your query but below resources may give you more insight VMFS/LUN size? - Yellow Bricks  Should I use many small LUNs or a couple large LUNs for Storage DRS? BEst...

View Article


Re: Files missing from datastores

Hi vmware,Should I consider those 11TB of data "dead"? I want to use the storage if I can't get the data back.I still wonder how 8 vmdk's just can dissapear.    

View Article

Unplanned PDL on ESXi 4.1

Hi, I just experienced a PDL on an ESXi host with my datastore.  I think I found my solution in the KB, but it seems the commands were for 5+.  I've searched very hard for similar esxcli commands for...

View Article


Image may be NSFW.
Clik here to view.

Re: HP VSA 11.0 (2014) - Bad storage performance

I just finished some more testing. The LSI SAS adapter is not compatible with VSA (it won't boot) and the LSI Parallel adapter does work, but it does not resolve the storage issues.  robocopy can still...

View Article

Snapshot cause server not reachable problem

In Our Setup, we got an alert stating "VM Server is not reachable",While analyzing this, we found that there is no space available on the host. When we move to different datastores, the issue resolved...

View Article

Re: Snapshot cause server not reachable problem

To avoid this you have two choices: 1. delete snapshot (VMware recommends preserve a snapshot for only 24-72 hours)2. move the VM to a datastore with sufficient space to support the growth of snapshot...